Scanning Probe Recognition Microscopy Investigation of Tissue Scaffold Properties

Abstract

Scanning probe recognition microscopy is a new scanning probe microscopy technique which enables selective scanning along individual nanofibers within a tissue scaffold. Statistically significant data for multiple properties can be collected by repetitively fine-scanning an identical region of interest. The results of a scanning probe recognition microscopy investigation of the surface roughness and elasticity of a series of tissue scaffolds are presented. Deconvolution and statistical methods were developed and used for data accuracy along curved nanofiber surfaces. Nanofiber features were also independently analyzed using transmission electron microscopy, with results that supported the scanning probe recognition microscopy-based analysis.

Introduction

Tissue scaffold engineering is an active and successful research fi eld (Atala 2005; Hu and Athanasiou 2006; Xu et al 2006) . However, much fundamental understanding is still needed to design scaffolds with the most appropriate mechanical, topographical and chemical properties for particular cells or cell classes. For actin-based cells, cell motility towards and adhesion to tissue scaffolds results from the extension of cell protrusions due to actin polymerization. Motility and adhesion are triggered through a complex interaction of receptors at the leading edge of the protrusion with the external environment ahead, as well as with the cell internal environment behind. Features of the cell internal environment have been recently reported (Svitkina et al 1996 (Svitkina et al , 1997 (Svitkina et al , 2003 Svitkina and Borisy 1999; Bear et al 2002; Vignjevic et al 2003; Biyasheva et al 2004) . The signalling cascades that trigger narrow fi lopodia and broad lamellipodia extension through assembly of actin fi laments into defi ned structures have been partly identifi ed. High resolution electron microscopy has identifi ed a strongly cross-linked actin polymerization with fi lopodia extension versus a widely-branched actin polymerization for lamellipodia extension. However, the combination of environmental factors that trigger the formation and continuance of actin polymerization of either extension type are still in need of elucidation. This is diffi cult because more than one environmental factor is known to stimulate leading edge formation. Cell sensing of surface roughness (haptotaxis) (Lampin et al 1997; Deligianni et al 2001; Gaudet et al 2003) , elasticity (durotaxis) (Pelham and Wang 1997; Lo et al 2000; Engler, Bacakova et al 2004; Engler, Richert et al 2004; Micoulet et al 2005; Discher et al 2005; Guo et al 2006; Gupta et al 2006) , and surface chemistry (chemotaxis) (Murray 2003; Arnold et al 2004; Stevens and George 2005) are all known to trigger cell motility through actin-based extension of fi lopodia and lamellipodia towards conditions which promote adhesion.

In the studies cited above, the surface roughness, elasticity and surface chemistry were all investigated separately for widely varying cell types that demonstrated the maximal response to each type of environmental trigger. There is a need to acquire the information for all pertinent environmental triggers that induce leading edge formation over the same location, and then to assemble them into a composite picture more truly representative of a cell’s perception of its environment.

Leading edge formation corresponds to a 10’s of nanometers sensing area at the cell’s extending tip. The environmental triggers should therefore be assessed on a comparable scale. Atomic force microscopy is an investigative tool with nanometer-scale resolution which may be used to investigate minimally conductive biological surfaces (Braga and Ricci 2003) . In the present studies, we use atomic force microscopy operated in a new mode, Scanning Probe Recognition Microscopy, to investigate the environmental triggers for cell response to a series of tissue scaffolds fabricated from electrospun carbon nanofi bers. Scanning Probe Recognition Microscopy is a new scanning probe microscopy technique which allows us to adaptively follow along individual nanofi bers within a tissue scaffold. Statistically signifi cant data for multiple properties can be collected and combined by repetitively fi ne-scanning over a region of interest. Using Scanning Probe Recognition Microscopy, we have investigated the surface roughness and elasticity of a series of three tissue scaffolds provided as a blind test. The tissue scaffolds were random nanofi ber meshes, with differences that resulted from different electrospinning conditions.

Tissue Scaffold Samples

Three samples of tissue scaffolds fabricated from electrospun (Taylor 1969; Dzenis 2004) carbon nanofi bers were obtained from the Donaldson Company. These will be referred to as samples A, B, and C. The nanofi bers were electrospun using an adapted electrospinning probe procedure described in the reference by (Chung et al 2004) . No further information about the tissue scaffolds samples was provided.

Nanoscope Iiia Special Sprm Modifi Cation

The scanning probe microscopy (SPM) experiments were performed using a Veeco Instruments Nanoscope IIIa operated in atomic force microscopy contact mode in ambient air (Binnig et al 1986; Bonnell 2001; Braga and Ricci 2003; Andrea and Paolo 2005) . The system has a special modifi cation developed by our research group in partnership with Veeco Instruments. The SPM system itself is given the ability to auto-track on regions of interest through incorporation of recognition -based tip control, described as scanning probe recognition microscopy (SPRM). The recognition capability is realized using algorithms and techniques from computer vision, pattern recognition and signal processing fi elds. Adaptive learning and prediction are also implemented to make detection and recognition procedures quicker and more reliable. The integration of recognition makes the SPRM system more powerful and fl exible in investigating specifi c properties of samples.

Other instrumental parameters include the use of a J scanner with a maximum 125 × 125 square micron x-y scan range and silicon nitride tips with a nominal 20 nm tip radius of curvature. Transmission electron microscopy (TEM) with selected area electron diffraction (SAED) was performed using a JEOL 100CXII TEM. Scanning electron microscopy (SEM) was performed using a Hitachi S-4700II fi eld emission SEM.

Experimental Results

Atomic force microscope (AFM) images of tissue scaffold samples A, B, and C are shown in Figures 1a-1c . Scanning electron microscope (SEM) images, shown in Figures 1d-1f , were also used to ensure that the AFM results were representative over larger scaffold areas. The general appearance of the nanofi bers was similar for samples A, B, and C. Tissue scaffold samples A, B, and C were then analyzed using Scanning Probe Recognition Microscopy for the more specifi c environmental triggers surface roughness and elasticity.

Surface Roughness

The surface roughness of the substrate has been shown to infl uence cell attachment. It is therefore important to obtain this information accurately and efficiently along tissue scaffold nanofi bers. In the majority of studies, the surface roughness is the Root Mean Square (RMS) of height values in a region of interest as defi ned in equation 1.

Rms

Z i Z ave i N N = − = ∑ ( ) 2 1 (1)

For AFM-based measurements, N is the number of total pixilated data points in this region; Z i is the height value at each pixel and Z N Z

ave i i N = ∑ = 1 1

is the average value of all height values.

Tissue Scaffold Properties

In conventional atomic force microscopy, the surface roughness information is acquired through manual application of a rectangular region of interest box (Digital Instruments 2003). The surface roughness within the box is then calculated. There are several problems with the conventional approach to surface roughness investigation when the sample is a tissue scaffold nanofi ber. The shape of the region of interest (ROI) may not be rectangular, necessitating the application of several small ROI boxes which follow the curvature of the nanofi ber. Only a single value is provided for each time of operation. Therefore, in order to get surface roughness along a nanofi ber, this operation would need to be repeated many times.

Figure 2 SPRM analysis of sample C (a) AFM images; (b) auto-tracking scan along three individual nanofi bers; (c) surface roughness map. Note that the apparent width of the nanofi ber is reduced from (b) as a result of the erosion operation; (d) elasticity map.

In the SPRM system, a recognition-based scan plan can be generated to auto-focus tip motion along an individual nanofi ber (Fan et al 2005) . The result of SPRM auto-track imaging versus traditional AFM raster imaging is shown by comparison of Figure 2 (b) with Figure 2(a). Also, adaptive scanning enables SPRM to fol low along an individual nanofi ber even when it crosses another nanofi ber as shown in Figure 2b . Therefore, the whole nanofi ber, or the whole nanofi ber mesh becomes the region of interest. Using data obtained by SPRM along individual nanofi bers, the surface roughness was calculated on each pixel based on a local neighborhood region. The shape and size of the local neighborhood region can be adjusted by the user, which makes the system adaptable for different samples. We chose a rectangular box around each pixel as the local neighborhood region, with a box size of 219.76 nm (close to the nanofi ber diameter). Multiple sets of overlapping surface roughness information were generated, with the provision that any box that extended outside the nanofi ber boundaries was automatically truncated. A surface roughness map along individual nanofi bers was then generated. Figure 2c shows a typical surface roughness map for sample C. Similar maps, not shown, were generated for samples A and B. In addition to the surface roughness maps, histograms showing the distribution of the surface roughness analyzed over several nanofi bers were calculated for samples A, B and C. This is the fi rst time that statistically meaningful information has been extracted along individual nanofi bers using an automatic procedure that maintains uniformity of experimental conditions.

Figure 3 Histograms of surface roughness (a) Sample A; (b) Sample B; (c) Sample C.
Table 1 Surface roughness statistical analysis Sample Data points Mode (nm) Mean (nm) Range (nm) Variance (nm2) A 3482 2.0 4.17 0.8 ∼ 19.7 9.1 B 5063 2.5 5.10 0.4 ∼ 20.0 15.5 C 12205 2.5 2.53 0.7 ∼ 7.4 1.2
Sample Data points Mode (nm) Mean (nm) Range (nm) Variance (nm2)
A 3482 2.0 4.17 0.8 – 19.7 9.1
B 5063 2.5 5.10 0.4 – 20.0 15.5
C 12205 2.5 2.53 0.7 – 7.4 1.2

The histograms of the surface roughness for samples A, B and C are shown in Figure 3 . From the histograms, the mode, the mean value, the range, and the variance of the surface roughness were investigated for several nanofi bers for each tissue scaffold sample. The distribution was also approximately analyzed. Table 1 shows the results from the statistical analysis of surface roughness.

The mode values were close for all three samples. The mean values might indicate a progression between the samples: Sample C (least) Ͻ Sample A Ͻ Sample B (greatest). However, the surface roughness distributions of samples A and B were wide spread with prominent tails and irregular values while the surface roughness distribution for sample C was narrow, peaked and smoothly connected. Analysis of the surface roughness distribution therefore indicated that sample C was different from samples A and B. The corresponding range and variance values further indicated that samples A and B were similar to each other but different from Sample C.

The histogram analysis shows the possibilities for misinterpretation of data using conventional AFM methods. The surface roughness mode values for the three samples were all very close. An individually applied ROI box would be most likely to return the mode value. However, the variances and distributions differed substantially between the samples. This was the true difference between the surface roughness of the samples, and it specifi cally indicated that sample C was different from samples A and B.

Elasticity

Atomic force microscopy can be used to measure elastic properties by collecting force curves over points on the surface of the sample. A single force curve records the force felt by the tip as it approaches and is then drawn away from the sample (Cappella and Dietler 1999; Butt et al 2005) . It is more useful to collect arrays of force curves across the sample surface at regular intervals and this is known as force volume imaging (Hoh et al 1997) . A force volume data set can be used to generate a 3-D map of interaction forces between the sample and tip.

The force curves in the force volume data set record the cantilever defl ection (d) versus the height of the sample surface (Z). Rather than using the sample surface position (Z), it is more useful to use the distance (D) which is the relative separation between the tip and the sample surface, and this is known as a force-distance curve. A force-distance curve (FD) is defi ned as the cantilever defl ection versus the absolute distance (D) between the tip and sample surface (D = Z -d). The Force Integration to Equal Limits (FIEL) (A-Hassan et al 1998) mapping method can be used to produce a robust measurement of relative elasticity. This method has the advantage of being independent of the tip-sample contact point, and of not requiring calibration of the AFM cantilever’s spring force constant. Using the Hertz model (Hertz 1881), which has been widely applied to AFM data, if the tip of an AFM is approximated by a sphere, then the force on the cantilever (F) can be defi ned from the indentation (δ), elastic modulus (E), Poisson ratio (v) and radius of the probe sphere

EQUATION (2): Not extracted; please refer to original document.

To compare the elastic properties at two different positions, a pair of FD curves is collected at positions P1 and P2 using the relative trigger mode (Digital Instruments 2003-2). At these points, the force F 1 equals force F 2 . The work done by the cantilever at each position is the area under a force-distance curve, and is given by

w Force d R k = ⋅ ∫ δ π δ δ 0 8 15 5 2 t t = /

(3) Therefore, the relationship between the elasticity and the force-distance curve at two different data positions is

w w k k 1 2 1 2 3 2 = ⎛ ⎝ ⎜ ⎞ ⎠ ⎟ / (4) where k v E = − 1 π

is inversely proportional to E, the elastic constant which represents the local elasticity of the sample. The area under the FD curve can be calculated and used to represent the inverse relative elasticity of the tissue scaffolding. Similar to Reference (A-Hassan et al 1998), this area value was used to compare the three samples.

Table 2 Elasticity/area map statistical analysis Sample Data points Mode (nm2) Mean (nm2) Range (nm2) Variance (nm4) A 1739 1780.0 1777.8 1953.6 ∼ 1961.4 4463.3 B 2757 1770.0 1747.5 1563.7 ∼ 1979.2 5760.5 C 6325 1730.0 1770.7 1602.5 ∼ 1961.4 4144.3
Sample Data points Mode (nm2) Mean (nm2) Range (nm2) Variance (nm4)
A 1739 1780.0 1777.8 1953.6 1961.4 4463.3
B 2757 1770.0 1747.5 1563.7 ~ 1979.2 5760.5
C 6325 1730.0 1770.7 1602.5 – 1961.4 4144.3

Each force curve in all three samples was triggered to exhibit the same maximum relative defl ection of 45 nm. The area map of sample C, generated using the FIEL method, is shown in Figure 2d . Area maps for samples A and B, not shown, were also generated using the same method. The histograms for samples A, B and C are shown in Figure 4 . As before, the mode, the mean value, the range, and the variance were investigated for each tissue scaffold sample, and the distribution was approximately analyzed. Table 2 shows the results from the statistical analysis of the elasticity.

Figure 4 Elasticity histograms for (a) Sample A; (b) Sample B; (c) Sample C.

The distribution of sample C was almost a normal distribution, while samples A and sample B had a symmetric but irregular distribution at both sides.

Two points were identifi ed from the histogram analysis. The fi rst was that samples A and B had similar distributions, but sample C had a different distribution even though the mode and mean of all three were close. The second was that sample B had the widest range, the largest variance and the most irregular distribution.

Curvature And Deconvolution

Figure 5 Circle fi t based on Kảsa method.

Our properties measurements by SPRM techniques were along individual nanofi bers, ie,along non-planar substrates. Two additional aspects considered in our analyses will now be discussed. Height data, Z, is used to calculate the surface roughness. This is acceptable for samples whose surfaces are relatively fl at because then the variation in height data will refl ect the variation in their surface roughness. This assumption is no longer appropriate for tissue scaffolds because the nanofibers have a cylindrical shape. Therefore, the variation of the height data, Z, includes not only its surface roughness variation, but also the variation caused by the shape. In Scanning Probe Recognition Microscopy, distance data, D, instead of height data, Z, was used to determine the real roughness of the sample surface. The Kảsa circle fi t method (Kasa 1976) was implemented to get the center (X center , Z center ) of the most fi tted circle as shown in Figure 5 . Then the distance

D i D Z Z X X i i center i center = − + − ( ) ( ) 2 2

(2) between each point on the surface and the center was evaluated and used to calculate the surface roughness maps and histograms.

Only the center part of the height data was used to fi nd the best fi t circle. The boundary regions are unreliable due to tipshape dilation effects. Dilation, or broadening of the image, is a result of the side of the tip coming into contact with the curved side of the nanofi ber (Keller 1991; Villarrubia 1994) . When an SPRM scan is focused on an individual nanofi ber, both the edge and center data is acquired. However, only the center part of the nanofi ber provides reliable data because of the tip convolution effect (Villarrubia 1997; Udpa et al 2006) . The ideal AFM would have an infi nitely sharp tip to reach as much of the surface as possible and an infi nitely sharp impulse response in its feedback system to instantly adjust the height of the tip as it is scanned over the surface.

D i Z i (X i Z i )

Figure 6 (a) Characteristic tip-dilation artifacts; (b) The cross section of a real AFM nano fi ber image and the best fi t circle.

In reality, the tip has a pyramidal or conical shape with some fi nite end radius so that it is durable enough to withstand the surface interaction forces. The effects of the tip shape cannot be avoided and these result in characteristic tip-dilation artifacts, as shown in Figure 6 . In the present work, we restricted our properties evaluations to regions of reliable data through the use of an erosion operation (Gonzalez and Woods 2002) . This is an important consideration when analyzing tissue scaffold nanofi ber geometries (instead of planar substrates) using AFM-based methods.

Nanofi Ber Diameter By Transmission Electron Microscopy

TEM images of several nanofi bers were taken to provide independent verifi cation of nanofi ber diameter, and from this, an estimate of the severity of tip-dilation artifacts present in the AFM images. Representative TEM images are shown in Figures 7a-7c . The nanofi ber diameter measurements within the TEM images were taken using Scion Image software (http://www.scioncorp.com). Scion Image was used to obtain a conversion factor relating pixels to nanometers using the scale bar in the lower right corner of the TEM images. Scion Image uses this conversion factor to measure lines drawn in the program’s image editor in units of physical length. For each TEM image, three measurements of the nanofi ber diameter were taken at distinct points along the length of the nanofi ber.

Table 3 Nanofi ber diameter measurements using TEM and AFM images Image Section 1 (nm) Section 2 (nm) Section 3 (nm) Mean (nm) Standard deviation (nm)
Image Section I (nm) Section 2 (nm) Section 3 (nm) Mean (nm) Standard deviation
TEM al 120 100 130 116.6667 12.47219
TEM a2 110 120 150 126.6667 16.99673
TEM a3 109.86 99.78 105.74 105.1267 4.137933
TEM bl 117.67 117.02 106.88 113.8567 4.94038
TEM b4 111.3 77.52 97.52 95.44667 13.86834
TEM b9 65.91 111.96 98.03 91.96667 19.28252
TEM b12 110.01 94.34 91.89 98.74667 8.026939
TEM c3 69.14 82.53 84.76 78.81 6.898063
TEM c4 390 380 350 373.3333 16.99673
TEM c5 390 380 350 373.3333 16.99673
TEM c7 312.96 313.21 309.12 311.7633 1.871903
TEM c8 351.19 348.64 329.44 343.09 9.707986
TEM c9 345.83 325.06 327.96 332.95 9.184164
TEM cll 345.71 346.33 345.36 345.8 0.401082
TEM cl4 415.95 388.83 345.04 383.2733 29.21432
TEM cl6 377.23 369.2 337.71 361.38 17.05524
AFM A 647 589.91 494,77 577.2267 62.79142
AFM B 781.25 722.66 742.19 748,7 24.35819
AFM C 761.72 800.78 644.53 735.6767 66.39381

Care was taken to identify fl uctuations in diameter that would be refl ected in the mean and variance of the measurements. Nanofiber diameter measurements within the AFM images were taken using the Nanoscope software. The software can be used to take a series of cross sections of the image orthogonal to the longitudinal axis of the nanofi ber being measured. These cross sections are returned to the user as 1-dimensional signals representing height versus distance parallel to the cross section. The software can then be used to position markers at various points along the signal, allowing the user to measure the distance between them. As in the TEM images, three measurements were taken at a variety of points along the length of the chief nanofi ber in each image. Variations in diameter were not as apparent in the AFM images, so care was taken to space the measurements evenly along the length of the nanofi ber. The discrepancy between the diameters measured using the TEM images and the diameters measured using the AFM images are given in Table 3 . Based on these measurements, a dilation factor of over 100% was estimated for AFM measurements of all three samples. These results are demonstrative of the severity of tip dilation effects in AFM techniques. As previously discussed, an erosion operation was applied to both the surface roughness and elasticity data to restrict the properties analysis to the most reliable data.

Nanofi Ber Properties By Transmission Electron Microscopy With Selected Area Electron Diffraction

Typical TEM images of samples A, B, and C with corresponding selective area electron diffraction (SAED) images are shown in Figures 7d and 7e . Samples A and B both showed a dark contrast outer layer surrounding a light contrast inner core, possibly hollow, while sample C was solid throughout. Diffraction images for samples A and B

showed prominent rings typical of disordered structures while diffraction images for sample C showed spots typical of an ordered (crystalline) structure. These results indicated that the atomic arrangement of sample C nanofi bers was substantially different from sample A and B nanofibers.

Close-up TEM images of samples B and C are shown in Figure 8 . These images are consistent with the normal and narrow surface roughness distribution of sample C as well as the wide variance and irregular surface roughness distribution of sample B. Therefore the TEM results were consistent with the results obtained by SPRM which consistently indicated (1) that sample C was different from both samples A and B, and (2) that samples A and B, while similar, had differences with sample B having the more extreme values.

Conclusions

Using SPRM, we have performed fi rst investigations of tissue scaffold properties directly along individual nanofi bers. We have investigated surface roughness and elasticity properties that have been shown to infl uence cell attachment. This is the fi rst time that statistically meaningful information has been extracted along individual nanofi bers using an automatic procedure that maintains uniformity of experimental conditions. The SPRM approach provided a wealth of data. Statistical methods based on histograms were developed to analyze the surface roughness and elasticity properties of the tissue scaffold nanofibers. The mode, mean range variance and distribution of surface roughness and elasticity were analyzed for tissue scaffold samples A, B and C. Sample C consistently showed properties that differed from samples A and B. The most prominent differences were observed in the surface roughness and elasticity distributions rather than in the individual mode values.

TEM with electron diffraction analysis confi rmed that both the structure and surface properties of sample C differed from those of samples A and B. The electron microscopy results were consistent with the results of the histogram analyses using SPRM generated data, including the large property variances and wide irregular distributions observed for sample B as well as for the small variances and narrow smooth distributions observed for sample C.

SPRM has the obvious advantage of saving operation time by scanning only regions of interest and ignoring other parts of the sample. This is especially useful for investigations of tissue scaffold properties, as a scaffold is composed of many individual nanofi bers. SPRM also enabled us to discriminate and use only the most reliable data from each nanofi ber for the properties evaluations. Tissue scaffold nanofi bers are curved surfaces while the conventional analyses are designed for fl at surfaces. In the present work, a Kasa circle fi t method is used to acquire the true surface roughness on a curved surface. An erosion operation was applied as the inverse operation to reverse the tip-shape dilation artifacts observable in AFM Section measurements and confi rmed by independent TEM measurements of nanofi ber diameter. In ongoing work, the hand-applied erosion operation will be replaced by automated erosion determined by mathematical morphology methods (Udpa et al 2006; Villarrubia 1997) .

Any property that can be investigated by scanning probe microscopy can be investigated by Scanning Probe Recognition Microscopy auto-tracking of a region of interest. Work is ongoing to develop SPRM-based surface chemistry investigations, as this is known to be an important property for cell motility and adhesion (Ahmed et al 2006) . Further work will develop data fusion methods that combine surface roughness, elasticity and surface chemistry information into a composite picture more truly representative of a cell’s perception its environment.

References

  • A-Hassan E, Heinz WF, Antonik MD, et al. 1998. Relative microelastic map- ping of living cells by atomic force microscopy. Biophys J, 74:1564-78.
  • Ahmed I, Liu H-Y, Mamiya PC, et al. 2006. Three-dimensional nanofi brillar surfaces covalently modifi ed with tenascin-C-derived peptides enhance neuronal growth in vitro. Journal of Biomedical Materials Research Part A, 76A:851-60.
    Conclusions
  • Braga PC, Ricci D. 2003. Atomic force microscopy: biomedical methods and applications. New Jersey: Humana Press.
    Introduction, Nanoscope Iiia Special Sprm Modifi Cation
  • Butt H-J, Cappella B, Kappl M. 2005. Force measurements with the atomic force microscope: Technique, interpretation and applications. Surface Science Reports, 59:1-152.
    Elasticity
  • Cappella B, Dietler G. 1999. Force-distance curves by atomic force micros- copy. Surface Science Reports, 34:1-104.
    Elasticity
  • Chung HY, Hall JRB, Gogins MA, et al. 2004. Polymer, polymer microfi ber, polymer nanofi ber and applications including fi lter structures. United States Patent No. 6743273, Donaldson Company, Inc.
    Tissue Scaffold Samples
  • Deligianni DD, Katsala ND, Koutsoukos PG, et al. 2001. Effect of surface roughness of hydroxyapatite on human bone marrow cell adhesion, proliferation, differentiation and detachment strength. Biomaterials, 22:87-96.
    Introduction
  • Digital. Instruments 2003. Chapter 14.6. Command reference manual. p. 381-400.
  • Discher DE, Janmey P, Wang Y-l. 2005. Tissue cells feel and respond to the stiffness of their substrate. Science, 310:1139-43.
    Introduction
  • Dzenis Y. 2004. Spinning continuous fi bers for nanotechnology. Science, 304:1917-19.
    Tissue Scaffold Samples
  • Engler A, Bacakova L, Newman C, et al. 2004. Substrate compliance versus ligand density in cell on gel responses. Biophys J, 86:617-28.
    Introduction
  • Engler AJ, Richert L, Wong JY, et al. 2004. Surface probe measurements of the elasticity of sectioned tissue, thin gels and polyelectrolyte multilayer fi lms: Correlations between substrate stiffness and cell adhesion. Surface Science, 570:142-54.
    Introduction
  • Micoulet A, Spatz JP, Ott A. 2005. Mechanical response analysis and power generation by single-cell stretching. Chem Phys Chem, 6:663-70.
    Introduction
  • Fan Y, Chen Q, Ayres VM, et al. 2005. Scanning probe recognition micros- copy investigation of cell elastic properties. 2005 APS March Meeting. Los Angeles, CA.
    Tissue Scaffold Properties
  • Gaudet C, Marganski WA, Kim S, et al. 2003. Infl uence of type I collagen surface density on fi broblast spreading, motility, and contractility. Biophys J, 85:3329-35.
    Introduction
  • Gonzalez RC, Woods RE. 2002. Digital image processing, Upper Saddle River, NJ: Prentice Hall.
    Curvature And Deconvolution
  • Guo W-H, Frey MT, Burnham NA, et al. 2006. Substrate rigidity regulates the formation and maintenance of tissues. Biophys J, 90:2213-20.
    Introduction
  • Gupta R, Geisberger A, Hughes G, et al. 2006. Manipulation of collagen for mechanical characterization. Zyvex Corporation.
    Introduction
  • Hertz H. 1881. Uber den Kontakt elastischer Köper. J Reine Angew Math- ematik, 92:156.
  • Hu JC, Athanasiou KA. 2006. A self-assembling process in articular cartilage tissue engineering. Tissue Eng, 12:969-79.
    Introduction
  • Kasa I. 1976. A curve fi tting procedure and its error analysis. IEEE Trans Inst Meas, 25:8-14.
    Curvature And Deconvolution
  • Keller D. 1991. Reconstruction of STM and AFM images distorted by fi nite-size tips. Surface Science, 253:353-64.
    Curvature And Deconvolution
  • Andrea A, Paolo F. 2005. AFM: a versatile tool in biophysics. Measurement Science and Technology, 16:R65-92.
    Nanoscope Iiia Special Sprm Modifi Cation
  • Lo C-M, Wang H-B, Dembo M, et al. 2000. Cell movement is guided by the rigidity of the substrate. Biophys J, 79:144-52.
    Introduction
  • Lampin M, Warocquier-Clérout R, Legris C, et al. 1997. Correlation between substratum roughness and wettability, cell adhesion, and cell migration. Journal of Biomedical Materials Research, 36:99-108.
    Introduction
  • Murray JD. 2003. Chapter 4. Mathematical biology II: spatial models and biomedical applications. 3rd ed. New York: Springer. p. 192-248.
    Introduction
  • Pelham RJ Jr, Wang Y-l. 1997. Cell locomotion and focal adhesions are regulated by substrate fl exibility. PNAS, 94:13661-5.
    Introduction
  • Stevens MM, George JH. 2005. Exploring and engineering the cell surface interface. Science, 310:1135-8.
    Introduction
  • Svitkina TM, Borisy GG. 1999. Arp2/3 Complex and actin depolymerizing factor/cofi lin in dendritic organization and treadmilling of actin fi lament array in lamellipodia. J Cell Biol, 145:1009-26.
    Introduction
  • Svitkina TM, Bulanova EA, Chaga OY, et al. 2003. Mechanism of fi lopodia initiation by reorganization of a dendritic network. J Cell Biol, 160:409-21.
    Introduction
  • Svitkina TM, Verkhovsky AB, Borisy GG. 1996. Plectin sidearms medi- ate interaction of intermediate fi laments with microtubules and other components of the cytoskeleton. J Cell Biol, 135:991-1007.
    Introduction
  • Svitkina TM, Verkhovsky AB, McQuade KM, et al. 1997. Analysis of the actin-myosin II system in fi sh epidermal keratocytes: mechanism of cell body translocation. J Cell Biol, 139:397-415.
    Introduction
  • Taylor G. 1969. Electrically driven jets. Proceedings of the Royal Society of London. Series A, Mathematical and Physical Sciences, 313:453-75. Tissue scaffold properties
    Tissue Scaffold Samples
  • Arnold M, Cavalcanti-Adam EA, Glass R, et al. 2004. Activation of integrin function by nanopatterned adhesive interfaces. Chem Phys Chem, 5:383-8.
    Introduction
  • Udpa L, Ayres VM, Yuan F, et al. 2006. Deconvolution of atomic force microscopy data for cellular and molecular imaging. Signal Processing Magazine, IEEE, 23:73-83.
    Curvature And Deconvolution, Conclusions
  • Vignjevic D, Yarar D, Welch MD, et al. 2003. Formation of fi lopodia-like bundles in vitro from a dendritic network. J Cell Biol, 160:951-62.
    Introduction
  • Villarrubia JS. 1994. Morphological estimation of tip geometry for scanned probe microscopy. Surface Science, 321:287-300.
    Curvature And Deconvolution
  • Villarrubia JS. 1997. Algorithms for scanned probe microscope image simu- lation, surface reconstruction, and tip estimation. Journal of Research of the National Institute of Standards and Technology, 102:425-54.
    Curvature And Deconvolution, Conclusions
  • Xu M, Kreeger PK, Shea LD, et al. 2006. Tissue-engineered follicles produce live, fertile offspring. Tissue Eng, 12:2739-46.
    Introduction
  • Atala A. 2005. Technology insight: applications of tissue engineering and biological substitutes in urology. Nat Clin Pract Urol, 2:143-9.
    Introduction
  • Bear JE, Svitkina TM, Krause M, et al. 2002. Antagonism between Ena/ VASP proteins and actin fi lament capping regulates fi broblast motility. Cell, 109:509-21.
    Introduction
  • Binnig G, Quate CF, Gerber C. 1986. Atomic force microscope. Physical Review Letters, 56:930.
    Nanoscope Iiia Special Sprm Modifi Cation
  • Biyasheva A, Svitkina T, Kunda P, et al. 2004. Cascade pathway of fi lopodia formation downstream of SCAR. J Cell Sci, 117:837-48.
    Introduction
  • Bonnell DA. 2001. Scanning probe microscopy and spectroscopy : theory, techniques, and applications, New York: Wiley-VCH.
    Nanoscope Iiia Special Sprm Modifi Cation

Leave a Reply

%d